Gypsemna Fire Rated Partition Wall

Single Layer Partition – G1 Series

Gypsemna Drywall Partition solutions are non load bearing, light weight, easy to install, yet robust –comprising of plasterboards screw fixed on either side to UC metal structures (Tracks and Studs), with joints taped and filled to get even smooth and homogenous surface.

  • Low weight in comparison to masonry walls of comparable thickness
    • Enhances saving in structural design
    • Suitable for high rise buildings
  • Quick and Easy to install
    • Cost effective
    • Reduced Project completion time
  • Performance
    • Fire protection – up to 1 hrs
    • Sound Insulation – up to 51 dB
    • Enhancement of fire & acoustic performance can be achieved by increasing the number of layers of plasterboards
    • Filling the cavity with insulation enhances the acoustic performance

Used as Partitions in commercial and residential buildings.

G1-Series–partition with single layer boards on either side of the UC metal structure. 

Component: 

Gypsum Plaster board

Based on the performance requirement, the plasterboard needs to be selected – RG for general applications; MR for humid and aerated area application; FW for enhanced fire resistance; TF for enhanced Impact resistance etc.

Tracks

Horizontal member of UC metal structure with equal 32mm minimum flange heights. In case of deflection the Top tracks have a flange height of minimum 50mm

Studs

Vertical member of UC metal structure with unequal flange heights( suitable for boxing of studs)

Anchors/plugs

Used for fixing the tracks to the slabs and floor respectively

Drywall screws

Used for screw fixing the boards to the metal structures; available as self tapping or self drilling

Joint tape and Filler

Used to get a even smooth and homogenous surface at the joints

Sealant

Applied at the perimeter areas, to achieve the necessary fire and acoustic performance

Insulation

Used as cavity infill to enhance sound insulation

Fixing channel / Noggins

Used as backing for horizontal edge cut joints in fire rated partitions

* Stud spacing and metal thickness will be determined by the partition height, deflection limit and lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions. 

Double Layer Partition – G2 Series

Gypsemna Drywall Partition solutions are non load bearing, light weight, easy to install, yet robust –comprising of plasterboard screw fixed on either side to UC metal structures (Tracks and Studs), with joints taped and filled to get even smooth and homogeneous surface.

  • Low weight in comparison to masonry walls of comparable thickness
    • Enhances saving in structural design
    • Suitable for high rise buildings
  • Quick and Easy to install
    • Cost effective
    • Reduced Project completion time
  • Performance
    • Fire protection – up to 3 hrs
    • Sound Insulation – up to 57 dB
    • Enhancement of fire & acoustic performance can be achieved by increasing the number of layers of plasterboards
    • Filling the cavity with insulation enhances the acoustic performance

Used as Partitions in commercial and residential buildings.

G2-Series–partition with multiple layer boards on either side of the UC metal structure. 

Product Standard:

Gypsum Plaster board

Based on the performance requirement, the plasterboard needs to be selected – RG for general applications; MR for humid and aerated area application; FW for enhanced fire resistance; TF for enhanced Impact resistance etc.

Tracks

Horizontal member of UC metal structure with equal 32mm minimum flange heights. In case of deflection the Top tracks have a flange height of minimum 50mm

Studs

Vertical member of UC metal structure with unequal flange heights( suitable for boxing of studs)

Anchors/plugs

Used for fixing the tracks to the slabs and floor respectively

Drywall screws

Used for screw fixing the boards to the metal structures; available as self tapping or self drilling

Joint tape and Filler

Used to get a even smooth and homogeneous surface at the joints

Sealant

Applied at the perimeter areas, to achieve the necessary fire and acoustic performance

Insulation

Used as cavity infill to enhance sound insulation

Fixing channel / Noggins

Used as backing for horizontal edge cut joints in fire rated partitions

* Stud spacing and metal thickness will be determined by the partition height, deflection limit and lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions. 

Certificate of Compliance : GYPSEMNA UL ONLINE CERTIFICATE

Triple Layer Partition – G3 Series

Gypsemna Drywall Partition solutions are non load bearing, light weight, easy to install, yet robust –comprising of plasterboards screw fixed on either side to UC metal structures (Tracks and Studs), with joints taped and filled to get even smooth and homogenous surface.

  • Low weight in comparison to masonry walls of comparable thickness
    • Enhances saving in structural design
    • Suitable for high rise buildings
  • Quick and Easy to install
    • Cost effective
    • Reduced Project completion time
  • Performance
    • Fire protection – up to 3 hrs
    • Sound Insulation – up to 61 dB
    • Enhancement of fire & acoustic performance can be achieved by increasing the number of layers of plasterboards
    • Filling the cavity with insulation enhances the acoustic performance

Used as Partitions in commercial and residential buildings.

G3-Series–partition with multiple layer boards on either side of the UC metal structure. 

Component:

Gypsum Plaster board

Based on the performance requirement, the plasterboard needs to be selected –  FW for enhanced fire resistance; TF for enhanced Impact resistance etc.

Tracks

Horizontal member of UC metal structure with equal 32mm minimum flange heights. In case of deflection the Top tracks have a flange height of minimum 50mm

Studs

Vertical member of UC metal structure with unequal flange heights( suitable for boxing of studs)

Anchors/plugs

Used for fixing the tracks to the slabs and floor respectively

Drywall screws

Used for screw fixing the boards to the metal structures; available as self tapping or self drilling

Joint tape and Filler

Used to get a even smooth and homogenous surface at the joints

Sealant

Applied at the perimeter areas, to achieve the necessary fire and acoustic performance

Insulation

Used as cavity infill to enhance sound insulation

Fixing channel / Noggins

Used as backing for horizontal edge cut joints in fire rated partitions


* Stud spacing and metal thickness will be determined by the partition height, deflection limit and lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions.

Chase Wall Partition – GH Series

GH Series – used for very high acoustic partitions, comprises of multiple layers of gypsum boards screw fixed on the outer side of the UC structure having parallel row of tracks and studs. The parallel rows of studs are braced by plasterboards or by metal profiles or by metal profiles through Acoustic V-brace, at defined horizontal heights for various acoustic performance requirements. Filling each stud cavity with acoustic insulation blanket, will enhance acoustical insulation as will do the sealing of the perimeters with Fire and Acoustic sealant that is at the same time providing the necessary air-tightness in case of fire.

Performance

  • Fire protection – up to 3 hrs
  • Sound Insulation – up to 72 dB

 

Component:

Gypsum Plaster board

Based on the performance requirement, the plasterboard needs to be selected – RG for general applications; MR for humid and aerated area application; FW for enhanced fire resistance; TF for enhanced Impact resistance etc.

Tracks*

Horizontal member of UC metal structure with equal 32mm minimum flange heights. In case of deflection the Top tracks have a flange height of minimum 50mm

Studs*

Vertical member of UC metal structure with unequal flange heights( suitable for boxing of studs)

Anchors/plugs

Used for fixing the tracks to the slabs and floor respectively

Drywall screws

Used for screw fixing the boards to the metal structures; available as self tapping or self drilling

Joint tape and Filler

Used to get a even smooth and homogenous surface at the joints

Sealant

Applied at the perimeter areas, to achieve the necessary fire and acoustic performance

Insulation

Used as cavity infill to enhance sound insulation

Fixing channel

Used as backing for horizontal edge cut joints in fire rated partitions

Bridging component

Plasterboard, Fixing channel and Acoustic V-B


 * Stud spacing and metal thickness will be determined by the partition height, deflection limit and lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions.

Staggered Wall Partition – GS Series

GS Series – used for acoustic partitions, comprises of single or double layers of gypsum boards screw fixed on the outer side of the UC structure having staggered row of studs, brace between top and bottom tracks and/or guide angles. The studs are not braced horizontally. Filling partition cavity with acoustic insulation blanket, will enhance acoustical insulation as will do the sealing of the perimeters with Fire and Acoustic sealant that is at the same time providing the necessary air-tightness in case of fire.

Performance

  • Fire protection – up to 2 hrs
  • Sound Insulation – up to 61dB

Component:

Gypsum Plaster board

Based on the performance requirement, the plasterboard needs to be selected – RG for general applications; MR for humid and aerated area application; FW for enhanced fire resistance; TF for enhanced Impact resistance etc.

Tracks/Guide Angles*

Horizontal member of UC metal structure

Studs*

Vertical member of UC metal structure with unequal flange heights( suitable for boxing of studs)

Anchors/plugs

Used for fixing the tracks to the slabs and floor respectively

Drywall screws

Used for screw fixing the boards to the metal structures; available as self tapping or self drilling

Joint tape and Filler

Used to get a even smooth and homogenous surface at the joints

Sealant

Applied at the perimeter areas, to achieve the necessary fire and acoustic performance

Insulation

Used as cavity infill to enhance sound insulation

Fixing channel

Used as backing for horizontal edge cut joints in fire rated partitions


* Stud spacing and metal thickness will be determined by the partition height, deflection limit and lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions.