Gypsemna Fire Rated Dry ceiling

Keylock Ceiling – GK Series

Gypsemna Ceiling solutions – comprising of a grid of completely concealed suspended metal frames (void of wire hangers and wire-clips) lined with gypsum plasterboards with its joints, treated (taped and filled) to achieve the even, smooth and homogenous surface – to receive paint or further decoration.

  • Light weight and versatile
    • Curvature and other special designs possible
    • Supports in concealing cableways, ducts etc
  • Very Quick and Easy to install
    • Cost effective
    • Reduced Project completion time
  • Performance
    • Fire protection – up to 2 hrs
    • Sound Insulation – up to 70 dB (when used under a concrete floor)
    • Enhancement of fire & acoustic performance can be achieved by increasing the number of layers of plasterboards
    • Filling the cavity with insulation on the back of the ceiling enhances of acoustic performance

GK Series–Gypsemna Rondo KEY-LOCK® Series – a versatile and very quick to install system suitable for fire and non-rated ceiling systems.

Test Standard : EN, ASTM, Thomas Bell-Wright

Component: 

Gypsum Plaster  board

Based on the performance requirement, the plasterboard needs to be selected – RG for general applications; MR for humid and aerated area application; FW for enhanced fire resistance; etc

Perimeter support

Furring Channels Tracks fixed at the perimeter on which Furring channel at 90° is friction fitted and board is screw fixed to its underside.

Primary Carrying Channel

Top Cross Rail (TCR) – Horizontal member at max. 1200mm* centres

Suspension system

Vertical member – a set of a bracket, a variable length suspension rod and an adjustable suspension clip, at max. 900mm* intervals.

Secondary Carrying Channel

Horizontal member -Furring channel running cross-wise fixed to the Main Channel by the Locking key at max. 600mm* centres

Anchors/plugs

Used for fixing the Suspension system to the slabs and Furring channel Tracks to the wall respectively at max. 600mm centres

Drywall screws

Used for screw fixing the boards to the metal structures; available as self tapping or self drilling

Joint tape and Filler

Used to get a even smooth and homogenous surface at the joints

Sealant

Applied at the perimeter areas, to achieve the necessary fire and acoustic performance

Insulation

Used as quilt covering the entire ceiling system will increase sound insulation in the void.Rockwool slabs are used to enhance the fire insulation.

*Primary and secondary channel centres, and suspension centres are determined by the number of layer of the boards, wind presure etc during the system design. Min. recommended thickness is 0.55mm.

Conventional Ceiling – GC Series

Gypsemna Ceiling solutions – comprising of a grid of completely concealed suspended metal frames (void of wire hangers and wire-clips) lined with gypsum plasterboards with its joints, treated (taped and filled) to achieve the even, smooth and homogenous surface – to receive paint or further decoration.

  • Light weight and versatile
    • Supports in concealing cableways, ducts etc
  • Quick and Easy to install
    • Cost effective
    • Reduced Project completion time
  • Performance
    • Fire protection – up to 2 hrs
    • Sound Insulation – up to 70 dB (when used under a concrete floor)
    • Enhancement of fire & acoustic performance can be achieved by increasing the number of layers of plasterboards
    • Filling the cavity with insulation on the back of the ceiling enhances of acoustic performance

GC Series– Suspended concealed system with Single or multiple layer Gypsum plaster boards, suitable for fire rated and non-fire rated ceiling systems.

Product Standard:

Gypsum Plaster         board                                

Based on the performance requirement, the plasterboard needs to be selected –RG for general applications; MR for humid and aerated area application; FW for enhanced fire resistance; etc.

Perimeter support

Wall angle fixed at the perimeter on which Furring channel at 90°is supported. The plasterboard is screw fixed to its underside.

Primary Carrying Channel

Main Channel (MC) – Horizontal member at max. 1200mm* centres, with 38mm minimum web width.

MC- Suspensions

Vertical member of variable length- identical to the Main Channel, screw fixed to the Main channel at max. 1200mm* intervals.

Secondary Carrying Channel

Hat shaped Furring channel running cross-wise and screw fixed to the Main Channel at max. 600mm* centres

Anchors/plugs

Used for fixing the MC-suspensions to the slabs and wall angles to the wall respectively at max. 600mm centres

Drywall screws

Used for screw fixing the boards to the metal structures; available as self tapping or self drilling

Joint tape and Filler

Used to get a even smooth and homogenous surface at the joints

Sealant

Applied at the perimeter areas, to achieve the necessary fire and acoustic performance

Insulation

Used as quilt covering the entire ceiling system will increase sound insulation in the void. Rockwool slabs are used to enhance the fire insulation.

* Main and Furring channel centres, MC-suspension interval will be determined while designing the system. Min. recommended metal thickness is 0.55mm.

T Grid Ceiling System

Technical Data Sheet: gypsemna-T-Grid Suspension System – asian international